Greenhouse
Indoor Garden
Climate Controllers
Interfacing Function Relays
|
|
|
|
Green Air Products
Model HAR-1
High Amperage Relay
The HAR-1 is a power relay that uses high amperage capacity contacts to transfer power to large fans or lighting systems requiring high voltage or amperage service. Use to operate 110 or 240 volt high draw equipment.
30 amp switch capacity with 110 volt trigger. Use in combination with any Green Air Timer of your choice. For complete operating instructions and usage examples, click here. |
|
|
|
|
| PLEASE NOTE: Many Green Air Products systems are built to order by the manufacturer. Please allow up to 2 weeks delivery time. Green Air Products do not qualify for express shipping options. |
|
|
|
|
Order #0016479
Green Air Products
Model HAR-1
High Amperage Relay
239.95 |
|
|
|
|
|
|
|
Green Air Products
Model IR-1
Interfacing Relay
The IR-1 plays an important role in the assembly and coordination of a total environmental control system. Atmostpheric controllers operate heaters, fans, coolers, etc. Timers control light cycles, irrigation and carbon dioxide equipment.
The IR-1 Interfacing Relay is a simple switching control that turns one or more of the listed functions OFF while others operate or to disable a function while others remain in service. |
|
|
|
|
As an example, in the hobby greenhouse, we would like to control the atmospheric conditions via thermostatically controlled exhaust ventilation 24 hours a day, but only want to enrich the air with carbon dioxide during the daylight hours. However, when exhaust fans are operating, injecting C02 into the atmosphere is pointless, since it will be immediately drawn out through the exhaust vents. The most common use for the IR-1 is to provide alternate switching for temperature or humidity controllers that do not already allow for carbon dioxide defeat during ventilation. Operates on 110 volts with a 15 amp switching capacity. For complete operating instructions and usage examples, click here.
PLEASE NOTE: Many Green Air Products systems are built to order by the manufacturer. Please allow up to 2 weeks delivery time. Green Air Products do not qualify for express shipping options. |
|
|
|
|
Order #0016512
Green Air Products
Model IR-1
Interfacing Relay
189.95 |
|
|
|
|
|
|
|

 |
Green Air Products
Model IR-2
Interfacing Relay
The IR-2 plays an important role in the assembly and coordination of a total environmental control system. The IR-2 provides the switching function to isolate two separate equipment controllers. The relay lets you function a single device with two independent controls and eliminates the possibility of power feedback.
Plug the IR-2 control pigtails into each of the controllers you want to use to regulate your equipment. The center power pigtail operates the left outlet which is defeated when the control outlet is activated. Plug it into a timer or other control device or directly into wall receptacle. |
|
|
|
|
|
| Ventilation characteristics vary during the year as seasons bring changes in temperature and humidity. During warm weather the thermostat and/or humidistat controller usually provides frequent enough air exchanges to maintain good air quality. In cooler weather this may not be the case and enclosed atmospheres could become stale or otherwise undesirable. A timed periodic exhaust cycle would insure ventilation regardless of atmospheric conditions. To have a synchronized system which provides both types of control automatically and simultaneously would be optimum. The timed sequence would maintain ventilation during normal conditions and the temperature and humidity sensors would intercede during extreme conditions. The IR-2 will coordinate these two control devices as well as override CO2 equipment during ventilation periods. |
|
|
|
|
|
The IR-2 can be applied to numerous switching scenarios using almost any combination of controllers and equipment functions. In this example we want to operate an exhaust fan with both a timer and atmospheric controller.
The CST-1 timer will function the exhaust fan according to the times set and the atmospheric controller will operate the exhaust fan depending on temperature or humidity conditions. Controllers may be plugged directly into wall outlets or into clock timers to limit functions to desired hours. |
 |
|
|
|
|
|
| CO2 equipment and controls could be operated by the left power outlet of the IR-2 which would be defeated during exhaust cycles. In the above example the timer would provide exhaust fan functions for air exchange periodically regardless of environmental conditions and the atmospheric controller would provide ventilation in the event of undesirable temperature or humidity levels. |
|
|
|
|
|
|
The example above demonstrates an irrigation scenario where as watering or misting can be regulated not only by timing but by temperature and humidity conditions as well. Irrigation would occur on a timed schedule routinely or if temperature exceeds setpoints or humidity drops below your desired level. The center power cord would not be needed in this operation. The CST-1P would defeat timer operation automatically during darkness hours. For more information, including complete operating instructions and usage examples, click here.
PLEASE NOTE: Many Green Air Products systems are built to order by the manufacturer. Please allow up to 2 weeks delivery time. Green Air Products do not qualify for express shipping options. |
|
|
|
|
|
|
Order #0016513
Green Air Products
Model IR-2
Dual Power Interfacing Relay
209.95 |
|
|
|
|
|
|
|
|
|
|
|

 |
Green Air Products
Model HF-1
High Amperage
Interfacing Relay
with Humidistat
The HF-1 is a high amperage relay with a built-in humidifying humidistat. Use to supply 110 or 240 volt power to humidifying equipment when humidity falls below a given set point. 30 amp switching capacity for heavy load requirements.
For more detailed information, including complete operating instructions and usage examples, click here. |
|
|
|
|
|
| PLEASE NOTE: Many Green Air Products systems are built to order by the manufacturer. Please allow up to 2 weeks delivery time. Green Air Products do not qualify for express shipping options. |
|
|
|
|
|
|
Order #0016514
Green Air Products
Model HF-1
High Amperage
Interfacing Relay
with Humistat
239.95 |
|
|
|
|
|
|
|
|
|
|
|

 |
Green Air Products
Model HR-1
High Amperage
Interfacing Relay
with External Coil
Heating Thermostat
The HR-1 is a high amperage relay with a built-in external coil heating thermostat. Use to supply 110 or 240 volt power to heating equipment when temperature falls below a given set point. Provides 30 amp switching capacity for heavy load requirements.
A jack receptacle and internal low voltage dry contacts are used to function gas type heaters. See MCC-1 installation description. For more information, including complete operating instructions and usage examples, click here. |
|
|
|
|
|
| PLEASE NOTE: Many Green Air Products systems are built to order by the manufacturer. Please allow up to 2 weeks delivery time. Green Air Products do not qualify for express shipping options. |
|
|
|
|
|
|
Order #0016515
Green Air Products
Model HR-1
High Amperage
Interfacing Relay
External Coil
Heating Thermostat
229.95 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|